PV-DEDPV by S&PDryer Exhaust Duct Power Ventilator

In-line/Sidewall Duct Fan Series

PV-DEDPV Model PV-DEDPV Model

Model Features

  • cULus 705 safety listed Dryer Exhaust Duct Power Ventilator for use with Gas or Electric clothes dryers
  • Complies with IRC and IMC codes
  • Automatic operation with an integral pressure sensor
  • 6' power cord
  • LED indicator light panel for operation status
  • Quick connect duct clamps and duct sections for easy maintenance
  • Backward inclined centrifugal impeller for high static pressure capability
  • Extend dryer duct length up to 120 feet
  • High-temperature thermal fuse for safety
  • Class F insulation
  • IP44 Motor protection

AMCA Seal for Air Performance   cULus Listed   HVI

Model Overview

The PV-DEDPV is a cULus 705 listed Dryer Exhaust Duct Power Ventilator. It effectively helps residential clothes dryers overcome the high static pressure caused by long duct runs between the dryer and wall or roof cap.

As laundry rooms move to more centralized locations in the home, longer and more complicated dryer duct runs are needed. These long runs cause an increase in static pressure that the integral clothes dryer fan cannot overcome. The International Mechanical Code (IMC) limits duct runs to 35 feet or less unless an engineering judgement can be made allowing a longer run. The long duct runs can cause a fire hazard because the clothes dryer fan cannot overcome the static pressure. This means the airflow is reduced causing longer drying times and more lint buildup in the ductwork. High temperatures and lint buildup are of serious safety concern in the dryer system.

The PV-DEDPV is an inline fan installed in clothes dryer systems to increase safety and allows architects/designers to locate the laundry room interior to the dwelling (instead of limiting them to only exterior walls) and still meet the  International Mechanical Code (IMC). This can be very helpful in multifamily applications where "interior units" can be sandwiched between other units creating long duct runs.

5-year fan housing and motor warranty

AMCA PERFORMANCE

 
Duct
(in)
Airflow (CFM) @ Static Pressure (in w.g.)  
Frequency
(Hz)
 
Voltage
(V)
Max
Power
(W)
Max
Current
(Amps)
Nominal
Speed
(RPM)
  0 0.125 0.25 0.375 0.50 0.75 1.0 1.25 1.50          
4 153 142 130 120 111 96 80 63 34 60 120 84 0.7 2880
Dimensional Drawing PV-DEDPV Dimensional Drawing PV-DEDPV