HR Heat Recovery Ventilator
Model Features
- Polypropylene HRV core
- 3 operating modes (Intermittent, Continuous and High Speed)
- DuotrolTM balancing system reduces noise that would be produced by balancing dampers
- Unique collar system for easy manipulation of duct for better and quicker installation
- Painted galvanized steel case
- Designed for simple installation by a single person
- Washable filters
- Fully insulated case
- HVI Certified
Model Overview
The S&P HR Series heat recovery ventilators (HRVs) are ideal for use in cold climates where home heating is essential. The HR Series uses one motor to exhaust stale room air and another motor to bring fresh outdoor air back into the house. The technology of a plate heat recovery core is that it transfers warm ambient air from one airstream to the other without mixing the air streams for maximum efficiency and comfort.
The HR Series has been engineered & designed to improve indoor air quality by reducing excess humidity and contaminants during the winter time, and replacing this air by fresh filtered air from the outdoors. During colder seasons, the units' heat recovery core (polypropylene core) will reclaim the heat from the outgoing stale air and use this heat to temper the incoming fresh air, which reduces the cost of effectively ventilating the home during winter. This process is reversed for summer months.
Limited lifetime core warranty and 5-year warranty on the unit balance.
Energy Performance (Heating)
Model | Supply | Net Air Flow | Power Consumed (Watts) | Sensible Recovery Efficiency | Apparent Sensible Effectiveness | ||
Temperature | |||||||
°F | °C | CFM | L/s | ||||
HR100V | 32 | 0 | 40 | 19 | 28 | 64 | 72 |
32 | 0 | 65 | 30 | 40 | 59 | 66 | |
-13 | -25 | 37 | 18 | 30 | 55 | 73 | |
HR160H | 32 | 0 | 65 | 31 | 72 | 66 | 75 |
32 | 0 | 83 | 39 | 80 | 63 | 72 | |
32 | 0 | 107 | 50 | 94 | 60 | 67 | |
-13 | -25 | 76 | 36 | 72 | 56 | 73 | |
HR220H | 32 | 0 | 118 | 55 | 106 | 61 | 71 |
32 | 0 | 160 | 75 | 132 | 58 | 65 | |
32 | 0 | 185 | 87 | 150 | 55 | 62 | |
-13 | -25 | 120 | 57 | 105 | 58 | 72 |
Ventilation Performance for HR100V
External Static Pressure | Net Air Flow | Gross Air Flow Supply | Gross Air Flow Exhaust | ||||
Pa | in. w.g. | L/s | CFM | L/s | CFM | L/s | CFM |
25 | 0.1 | 47 | 99 | 48 | 100 | 48 | 102 |
50 | 0.2 | 44 | 93 | 45 | 94 | 43 | 92 |
75 | 0.3 | 39 | 83 | 40 | 84 | 38 | 80 |
100 | 0.4 | 35 | 75 | 35 | 75 | 36 | 78 |
125 | 0.5 | 30 | 65 | 30 | 66 | 32 | 68 |
150 | 0.6 | 27 | 56 | 27 | 57 | 25 | 52 |
175 | 0.7 | 22 | 46 | 22 | 47 | 19 | 41 |
Ventilation Performance for HR160H
External Static Pressure | Net Air Flow | Gross Air Flow Supply | Gross Air Flow Exhaust | ||||
Pa | in. w.g. | L/s | CFM | L/s | CFM | L/s | CFM |
25 | 0.1 | 91 | 193 | 91 | 194 | 103 | 217 |
50 | 0.2 | 84 | 178 | 85 | 179 | 95 | 201 |
75 | 0.3 | 77 | 163 | 77 | 163 | 86 | 183 |
100 | 0.4 | 71 | 150 | 71 | 151 | 80 | 169 |
125 | 0.5 | 63 | 133 | 63 | 134 | 71 | 152 |
150 | 0.6 | 57 | 120 | 57 | 121 | 66 | 138 |
175 | 0.7 | 51 | 109 | 51 | 109 | 57 | 121 |
Ventilation Performance for HR220H
External Static Pressure | Net Air Flow | Gross Air Flow Supply | Gross Air Flow Exhaust | ||||
Pa | in. w.g. | L/s | CFM | L/s | CFM | L/s | CFM |
25 | 0.1 | 117 | 248 | 118 | 250 | 130 | 277 |
50 | 0.2 | 108 | 229 | 109 | 231 | 119 | 253 |
75 | 0.3 | 102 | 218 | 103 | 220 | 110 | 234 |
100 | 0.4 | 94 | 200 | 95 | 202 | 101 | 216 |
125 | 0.5 | 85 | 181 | 86 | 183 | 92 | 197 |
150 | 0.6 | 77 | 163 | 78 | 165 | 82 | 175 |
175 | 0.7 | 69 | 146 | 70 | 148 | 71 | 151 |
Dimensions for HR100V
Dimensions for HR160H
Dimensions for HR220H
Note: Additional accessories are available for certain products. Contact your JencoFan Representative for more information about these accessories.
Standard Accessories
- General/Clean Air
- Contaminated Air
- Heat Recovery